QClad
QClad
T-2026-0131 Demo Herston Health Precinct, Plantroom Acoustic Enclosures
Accounting connected Wed 5 Aug 2026
T-2026-0131 Drafting Commercial PRJ-2026-051

Herston Health Precinct, Plantroom Acoustic Enclosures

Hutchinson Builders · Herston, Brisbane

Issued 24 Jul 2026 · closes 21 Aug 2026 · valid 60 days · Dylan Fraser

Priced but not lodged. The acoustic report is the whole risk: if 38 dB(A) is measured at the boundary rather than at 1m, the enclosure spec changes.

Price, ex GST

$1,054,494

Cost build-up

$850,272

Margin

$204,222 19%

Markup applied

22%

on the cost build-up

QClad

Roofing · Cladding · Acoustics

Tender

T-2026-0131

Valid 60 days from 24 Jul 2026

To

Hutchinson Builders

Danielle Whyte, Contracts Administrator

dwhyte@hutchinsonbuilders.com.au

ABN 27 009 778 129

Project

Herston Health Precinct, Plantroom Acoustic Enclosures

Herston, Brisbane

Sector: Commercial

Tender closes 21 Aug 2026

Scope of works

Supply and install acoustic enclosures, absorption panel, liner tray and isophonic mounts to four rooftop plantrooms, with independent verification testing to 38 dB(A) at the boundary.

Schedule of rates

ItemQtyRate, ex GSTAmount
Preliminaries
RS-PRE-MOB Mobilisation & site establishment 1 item $18,450.00 $18,450.00
RS-PRE-SWM SWMS, JSA & site-specific safety plan 1 item $2,680.00 $2,680.00
RS-PRE-SUP Site supervision, leading hand 74 day $1,248.00 $92,352.00
RS-PRE-DEM Demobilisation & make good 1 item $7,420.00 $7,420.00
Acoustics
RS-ACO-ENC Plant acoustic enclosure, fabricate and install 480 m² $482.00 $231,360.00
RS-ACO-PNL Acoustic absorption panel, install 1,180 m² $229.00 $270,220.00
RS-ACO-LIN Perforated acoustic liner tray, install 620 m² $264.00 $163,680.00
RS-ACO-ISO Isophonic bracket & resilient mount system 1,180 m² $89.40 $105,492.00
RS-ACO-TST Post-installation acoustic verification test 1 item $4,280.00 $4,280.00
Wall cladding
RS-CLD-LOU Weatherproof louvre panel, install 240 m² $346.00 $83,040.00
Height access
RS-HGT-SPI Spider lift hire & operator, 28m 32 day $2,360.00 $75,520.00
Total, ex GST$1,054,494.00
GST at 10%$105,449.40
Total, inc GST$1,159,943.40

Exclusions

  • · Structural steel to support the enclosures
  • · Electrical isolation and reinstatement
  • · Crane hire beyond the allowance shown
  • · Asbestos identification or removal

This tender is valid for 60 days from 24 Jul 2026 and is subject to QClad's standard conditions of subcontract. Quantities are measured from the tender documents and re-measured on completion. Payment terms BIF 15/25, retention 5%. All personnel hold current White Card, working-at-heights and site-specific inductions.

Dylan Fraser, Estimating Manager · QClad Services Pty Ltd · ABN 62 138 704 915 · QBCC 1174 320